Spectrum-controls 1734sc-IF4U Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Měřící nástroje Spectrum-controls 1734sc-IF4U. Spectrum Controls 1734sc-IF4U User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk

Shrnutí obsahu

Strany 1 - Point IO™

User’s Manual Pub. 0300266-01 Rev. A Point IO™ 4 Universal Analog Input Module Catalog Number: 1734sc-IF4U

Strany 2 - Important Notes

1-4 Point IO™ 4 Channel Universal Analog Input Module User’s Manual Pub. 0300266-01 Rev. A Indicator State Description Flashing Green Device nee

Strany 3 - Table of Contents

Chapter 1: Module Overview 1-5 User’s Manual Pub. 0300266-01 Rev. A 1.6.1 Module Power-up At power-up, the module performs a check of its internal

Strany 4

1-6 Point IO™ 4 Channel Universal Analog Input Module User’s Manual Pub. 0300266-01 Rev. A

Strany 5 - Used in This

User’s Manual Pub. 0300266-01 Rev. A Chapter 2 Installation and Wiring This chapter will cover:  Compliance to European union directives  Power

Strany 6

2-2 Point IO™ 4 Channel Universal Analog Input Module User’s Manual Pub. 0300266-01 Rev. A 5 VDC 24 VDC 15 mA (max) 20 mA (max) Use the table b

Strany 7 - Module Overview

Chapter 2: Installation and Wiring 2-3 User’s Manual Pub. 0300266-01 Rev. A 2.3.2 Prevent Electrostatic Discharge !Attention Electrostatic dischar

Strany 8

2-4 Point IO™ 4 Channel Universal Analog Input Module User’s Manual Pub. 0300266-01 Rev. A wiring base assembly is one of the following:  1734-T

Strany 9 - 1.5.1 LED Indicators

Chapter 2: Installation and Wiring 2-5 User’s Manual Pub. 0300266-01 Rev. A 2.4.2 Install Mounting Base !Attention During panel or DIN rail mount

Strany 10 - Overview

2-6 Point IO™ 4 Channel Universal Analog Input Module User’s Manual Pub. 0300266-01 Rev. A 1.) Using a bladed screwdriver, rotate the key switch

Strany 11 - 1.6.2 Module Operation

Chapter 2: Installation and Wiring 2-7 User’s Manual Pub. 0300266-01 Rev. A vertical position. This releases the locking mechanism. 7.) Lift strai

Strany 12

ii Point IO™ 4 Channel Universal Analog Input Module User’s Manual Pub. 0300266-01 Rev. A Important Notes 1. Please read all the information in t

Strany 13 - Installation and Wiring

2-8 Point IO™ 4 Channel Universal Analog Input Module User’s Manual Pub. 0300266-01 Rev. A Grounding !Attention USE SUPPLY WIRES SUITALE FOR 10°C

Strany 14 - General

Chapter 2: Installation and Wiring 2-9 User’s Manual Pub. 0300266-01 Rev. A Note: The CJC sensor shown in the diagram above can only be install

Strany 15 - Attention

2-10 Point IO™ 4 Channel Universal Analog Input Module User’s Manual Pub. 0300266-01 Rev. A

Strany 16

User’s Manual Pub. 0300266-01 Rev. A Chapter 3 Configuring the 1734sc-IF4U Using RSLogix 5000 This chapter covers the following subjects:  Things

Strany 17 - 2.4.2 Install Mounting Base

3-2 Point IO™ 4 Channel Universal Analog Input Module User’s Manual Pub. 0300266-01 Rev. A !Attention The IF4U module is not compatible with the

Strany 18 - 2.4.5 Remove a Mounting Base

Chapter 3: Configuring the 1734sc-IF4U for RSLogix 5000 3-3 User’s Manual Pub. 0300266-01 Rev. A Note: When you create a new RSLogix 5000 projec

Strany 19 - Connections

3-4 Point IO™ 4 Channel Universal Analog Input Module User’s Manual Pub. 0300266-01 Rev. A 3.) Configure the local Ethernet bridge module. 3.3.2

Strany 20 - 2.5.1 Wiring Diagram

Chapter 3: Configuring the 1734sc-IF4U for RSLogix 5000 3-5 User’s Manual Pub. 0300266-01 Rev. A 2.) Select the module type from the Select Mod

Strany 21

3-6 Point IO™ 4 Channel Universal Analog Input Module User’s Manual Pub. 0300266-01 Rev. A 3.3.3 Add the Generic Point IO Module After adding the

Strany 22

Chapter 3: Configuring the 1734sc-IF4U for RSLogix 5000 3-7 User’s Manual Pub. 0300266-01 Rev. A 3.) Configure the Generic 1734 Module (i.e. 17

Strany 23 - Using RSLogix 5000

iii User’s Manual Pub. 0300266-01 Rev. A Table of Contents IMPORTANTNOTES...

Strany 24 - Profile

3-8 Point IO™ 4 Channel Universal Analog Input Module User’s Manual Pub. 0300266-01 Rev. A 3.4.1 Installing the Add-On profile 1.) Download the z

Strany 25

Chapter 3: Configuring the 1734sc-IF4U for RSLogix 5000 3-9 User’s Manual Pub. 0300266-01 Rev. A 4.) Highlight the module and press the “OK” bu

Strany 26

3-10 Point IO™ 4 Channel Universal Analog Input Module User’s Manual Pub. 0300266-01 Rev. A 7.) Configure the rest of the module using the “Mod

Strany 27

Chapter 3: Configuring the 1734sc-IF4U for RSLogix 5000 3-11 User’s Manual Pub. 0300266-01 Rev. A Generic Module Profile: [Name of remote communi

Strany 28

3-12 Point IO™ 4 Channel Universal Analog Input Module User’s Manual Pub. 0300266-01 Rev. A 3.5.1 Channel Configuration Details To Select Make th

Strany 29 - Add-On-Profile

Chapter 3: Configuring the 1734sc-IF4U for RSLogix 5000 3-13 User’s Manual Pub. 0300266-01 Rev. A Channel Disable (Bit 0) Enable(Default)=0,

Strany 30

3-14 Point IO™ 4 Channel Universal Analog Input Module User’s Manual Pub. 0300266-01 Rev. A ignored.Itisrecommendedtoconfigurebothchannels

Strany 31 - Name the module

Chapter 3: Configuring the 1734sc-IF4U for RSLogix 5000 3-15 User’s Manual Pub. 0300266-01 Rev. A Input Range Input Value Condition EU x1 EU

Strany 32 - Configuration

3-16 Point IO™ 4 Channel Universal Analog Input Module User’s Manual Pub. 0300266-01 Rev. A 2/3/4 Wire RTD (Bits 13 and 14) Thesebitsareusedfo

Strany 33

Chapter 3: Configuring the 1734sc-IF4U for RSLogix 5000 3-17 User’s Manual Pub. 0300266-01 Rev. A Table 3-4 (IF4U Input Assembly) Instance: De

Strany 34

iv Point IO™ 4 Channel Universal Analog Input Module User’s Manual Pub. 0300266-01 Rev. A PREFACERead this preface to familiarize yourself with t

Strany 35

3-18 Point IO™ 4 Channel Universal Analog Input Module User’s Manual Pub. 0300266-01 Rev. A

Strany 36

User’s Manual Pub. 0300266-01 Rev. A Appendix A Module Specifications General Specifications Parameter Specification Module location 1734-TBxx Poin

Strany 37

A-2 Point IO™ 4 Channel Universal Analog Input Module User’s Manual Pub. 0300266-01 Rev. A Input Specifications Input Specification Inputs per modul

Strany 38 - Read Input

Appendix A: IF4U Specifications A-3 User’s Manual Pub. 0300266-01 Rev. A Input Specification Type J: ± 0.9°C maximum Type T (-230°C to 400°C): ± 1

Strany 39

A-4 Point IO™ 4 Channel Universal Analog Input Module User’s Manual Pub. 0300266-01 Rev. A Environmental Specifications Environmental Tests Industr

Strany 40

Appendix A: IF4U Specifications A-5 User’s Manual Pub. 0300266-01 Rev. A Environmental Tests Industry Standards Test Level Limits Conducted RF imm

Strany 41 - Module Specifications

A-6 Point IO™ 4 Channel Universal Analog Input Module User’s Manual Pub. 0300266-01 Rev. A

Strany 42 - Input Specifications

User’s Manual Pub. 0300266-01 Rev. A Index AAdd‐On‐Profile∙3‐7Bblockdiagram∙1‐5EEMCDirective∙2‐1FFieldWiringConnections∙2‐7Filte

Strany 43

User’s Manual Pub. 0300266-01 Rev. A

Strany 44 - Environmental Specifications

User’s Manual Pub. 0300266-01 Rev. A Getting Technical Assistance Note that your module contains electronic components which are susceptible to dam

Strany 45 - Agency Certifications

v User’s Manual Pub. 0300266-01 Rev. A If you would like a manual, you can:  Download a free electronic version from the internet at www.theautom

Strany 46

User’s Manual Pub. 0300266-01 Rev. A ©2012, Spectrum Controls, Inc. All rights reserved. Specifications subject to change without notice. The Encom

Strany 47

vi Point IO™ 4 Channel Universal Analog Input Module User’s Manual Pub. 0300266-01 Rev. A

Strany 48

User’s Manual Pub. 0300266-01 Rev. A Chapter 1 Module Overview The 1734sc-IF4U module has four analog input channels that support current, voltage,

Strany 49 - Conformity

1-2 Point IO™ 4 Channel Universal Analog Input Module User’s Manual Pub. 0300266-01 Rev. A Section 1.3 Data Formats For each channel the data can

Strany 50

Chapter 1: Module Overview 1-3 User’s Manual Pub. 0300266-01 Rev. A Figure 2 1.5.1 LED Indicators The 1734 analog HART module uses several LEDs

Komentáře k této Příručce

Žádné komentáře